At the first, I would like to say thanks to Ms Pugsy for her help. I successfully bought ResMed S10 AirSense AutoSet + Nasal pillows ResMed AirFit P10. In spite of "warnings and threats" from local Canadian representatives who sell CPAP machines here, my machine and mask were delivered from the USA to Canada without any problems.
I set my machine according to prescription (auto, 5-18 H2O) and already have 7 days of therapy.
Unfortunately, I don't see any improvement in my condition. As previously, I feel sleepiness and drowsiness all day and only in the evening I feel myself normally. So, I don't feel refreshed after sleep.
But according to results of my machine statistic is good.
May be I missed something? Maybe I have to adjust my settings?
Here my statistic:
CPAP settings:
APAP with min 5 and max 18 (cm H2O)
EPR: full time 1 cm H2O
Humidity level 4
Mask Pillows
Temperature 27 C
Temperature enable 2
CPAP usage
Average Hours per Night 07:07
Compliance 100%
Therapy Efficacy
AHI 1.30
Obstructive Index 0.10
Hypopnea Index 0.32
Clear Airway Index 0.84
RERA Index 0.12
Leak Statistics
Average Leak Rate 7.27
90% Leak Rate 0.00
% of time above Leak Rate threshold 4.28%
Pressure Statistics
Average Pressure 6.42
Min Pressure 4.14
Max Pressure 11.20
90% Pressure 0.00
Average EPAP 5.47
Min EPAP 4.02
Max EPAP 10.20
This is an example of last night:

Surprisely, I found a lot of "clear airway events", some of them kind of false:

But there are also CAs which resemble really central apnea compexes: