The RemStar Auto when on 12vdc power has a max current draw of 3 amps. It is only 1 amp on 120vac. Based on that a 22 amp hr battery will give you at best 7 hours at full current. Your time would increase depending on the pressure level it runs at. The lower the pressure the longer run time you coul...
by Handgunner45
Mon Sep 17, 2007 8:46 am
Forum: CPAP and Sleep Apnea Message Board
Topic: Sleep Study @ a Veterans Hospital?
Replies: 7
Views: 3161

I got my sleep study done by the VA. Took 3 months after my GP agreed that I needed a study until I was able to see the "sleep specialist", and after he agreed that I needed the study, took another 3 months to get in for the study. They did a split night and I left the hospital the next morning with...
by Handgunner45
Fri Sep 07, 2007 1:29 pm
Forum: CPAP and Sleep Apnea Message Board
Topic: full face mask users-need opinions
Replies: 28
Views: 4189

Ultra Mirage Full Face since my first night of CPAP. My one and only mask. I got lucky and found my ideal mask right off the bat.

by Handgunner45
Thu Sep 06, 2007 10:34 am
Forum: CPAP and Sleep Apnea Message Board
Topic: opposite sex and cpap
Replies: 185
Views: 25223

Sorry Babette, but I think the only way that modern science has found to remove the female sex drive is for her to get married .


Worked for my first 3 wives......... .
by Handgunner45
Fri Aug 10, 2007 8:34 am
Forum: CPAP and Sleep Apnea Message Board
Topic: Server Upgrade Scheduled
Replies: 66
Views: 11220

Losing the new posts on thread flag. After reading one new post and going back to the list it shows that none of the threads have new posts.
by Handgunner45
Tue Aug 07, 2007 7:31 am
Forum: CPAP and Sleep Apnea Message Board
Topic: How does one become a Polysomnograph Tech?
Replies: 12
Views: 2058

Try here to start.
http://www.aastweb.org/
by Handgunner45
Wed Jul 25, 2007 7:09 am
Forum: CPAP and Sleep Apnea Message Board
Topic: RemStar Pro error code 36?
Replies: 4
Views: 1255

From the service manual for the Remstar Pro 2/Auto


E-36
ERR_NVDATA_RANGE_FAILURE
•Defective EEPROM
•Replace Main PCA
by Handgunner45
Fri Jul 13, 2007 8:45 am
Forum: CPAP and Sleep Apnea Message Board
Topic: Setting the date on Respironics BiPap machines
Replies: 4
Views: 949

Actually anyone that has an account with respironics as a provider can have access to the software and cabling necessary to adjust the real time clock in the unit. Because we use these units where I work, I have the software and cabling for it. When you do the RTC calibration to the unit it adjusts ...
by Handgunner45
Tue Jul 03, 2007 8:23 am
Forum: CPAP and Sleep Apnea Message Board
Topic: Off topic
Replies: 5
Views: 1179

With the new chemicals that they use for treated lumber you no longer want to use the cement coated nails. They will still rust, unless you are using untreated wood. With the older treated lumber they recommended cement coated so that they would not be destroyed by the chemicals that were used to tr...
by Handgunner45
Thu Jun 28, 2007 7:05 am
Forum: CPAP and Sleep Apnea Message Board
Topic: Smart Card - download capabilities Stupid DME's
Replies: 12
Views: 1469

Christy223 wrote:OK Respironics M Series Pro comes with smart card - then I have to purchase software on my own to download info. Is this correct? I just don't to get the shaft from some DME that thinks I am stupid!!!

_________________

Thats the way it works. You will also have to purchase the card reader.

by Handgunner45
Mon Jun 11, 2007 10:25 am
Forum: CPAP and Sleep Apnea Message Board
Topic: Error Code E-77
Replies: 5
Views: 5604

E 77 indicates the pressure sensor is not putting out a signal, either because the sensor is not getting pressure applied to it or the sensor is bad. You would have to open the unit and look to ensure the tube is still connected and not blocked. If it all looks alright, it is a matter of replacing t...
by Handgunner45
Wed Jun 06, 2007 1:38 pm
Forum: CPAP and Sleep Apnea Message Board
Topic: RemStar Error Code E-07
Replies: 2
Views: 1178

E-7 is a stack overflow error. RAM is bad in machine. Have to replace the main PC board.

Probably more cost efficient to go this way.

https://www.cpap.com/productpage-advanced.php?PNum=716
by Handgunner45
Wed May 30, 2007 6:57 am
Forum: CPAP and Sleep Apnea Message Board
Topic: Sealing and Shaving
Replies: 12
Views: 2295

I wear a beard and moustache and use the UMFF. No problem with seals. Maybe a little more leakage than some but not enough to be a problem.
by Handgunner45
Fri May 18, 2007 2:01 pm
Forum: CPAP and Sleep Apnea Message Board
Topic: Any schematics for Remstar
Replies: 20
Views: 2644

Of those 10 types of people I am in the former. If you spend any time working on medical equipment you will quickly find that most equipment manufacturers have proprietary chips manufactured for their medical devices. This precludes the average tech from repairing to the component level and ensures ...
by Handgunner45
Tue May 15, 2007 11:45 am
Forum: CPAP and Sleep Apnea Message Board
Topic: Still machine shopping, Is this a good one?
Replies: 6
Views: 1178

Thats the unit I use. Works great for me. Has full data capability. If you are happy using a CPAP vs an APAP, it is a very good machine.