Cleaning EncorePro Smartcard

This morning EncorePro could not read my Smartcard. After several removal/re-insertions of the card there was no joy. Previously I had cleaned the gold contacts on the card with an art gum eraser, but several days ago I had purchased some electronic contact cleaner for my growing collection of LED f...
by Hugh
Wed Nov 23, 2005 8:33 pm
Forum: CPAP and Sleep Apnea Message Board
Topic: Remstar Auto w/ C-Flex-- Auto On doesn't work anymore???
Replies: 9
Views: 1882

To eliminate possible mask problems regarding your autostart problem: Disconnect the CPAP tubing from the mask, place mouth over end of tubing and do several blow/sucks. If the machine starts, you have a mask problem.

by Hugh
Fri Jul 08, 2005 11:21 am
Forum: CPAP and Sleep Apnea Message Board
Topic: REMstar Heated Humidifier Frustrations
Replies: 20
Views: 3563

Hugh's Autostart Test Procedure Without Mask 1. Close bedroom door and draw blinds/curtains. Dim the lights. 2. Disconnect hose from mask. 3. Insert end of hose in mouth. 4. Close lips firmly around end of hose. 5. Blow out and suck in on end of hose at least 5 times. 6. When machine starts, remove...
by Hugh
Thu Jul 07, 2005 10:04 pm
Forum: CPAP and Sleep Apnea Message Board
Topic: REMstar Heated Humidifier Frustrations
Replies: 20
Views: 3563

My autostart takes 3 - 5 breaths to start, but has never failed to start the machine. The necessity to hit the start button more than once suggests a problem. I would suggest contacting your DME or Respironics directly.
by Hugh
Wed Jul 06, 2005 11:39 am
Forum: CPAP and Sleep Apnea Message Board
Topic: REMstar Heated Humidifier Frustrations
Replies: 20
Views: 3563

but missed one step... push heater on button Last night I hit upon a partial solution to the above problem. When I turned my REMstar OFF, I immediately turned the heated humidifier back ON. This puts the humidifier in preheat mode for 20 minutes. But, if your potty break lasts more than 20 minutes ...
by Hugh
Tue Jul 05, 2005 11:58 pm
Forum: CPAP and Sleep Apnea Message Board
Topic: REMstar Heated Humidifier Frustrations
Replies: 20
Views: 3563

Plus that TINY green light that can't be seen very easily if you place the machine down low is a REAL joke. I considered a system of mirrors so I can see the light to see if I actually remembered to turn it on when I go to sleep or during the night. Please see my post http://cpaptalk.com/viewtopic....
by Hugh
Sat Jun 11, 2005 5:21 pm
Forum: CPAP and Sleep Apnea Message Board
Topic: APAP, Night One
Replies: 9
Views: 2420

Most nights my Encore software shows that the average leak is 35 - 38 cm H2O, but on occasion has gone as high as 43 cm H2O. The above should read: "Most nights my Encore software shows that the average leak is 35 - 38 liters per minute, but on occasion has gone as high as 43 liters per minute." So...
by Hugh
Sat Jun 11, 2005 5:08 pm
Forum: CPAP and Sleep Apnea Message Board
Topic: APAP, Night One
Replies: 9
Views: 2420

what you you feel is a acceptable leak average over the course of a night? The literature that came with your mask should have a chart showing the leak pressure through the exhaust vents. This varies depending upon the pressure setting of the xPAP. In my case, the chart shows that my ResMed Active ...
by Hugh
Wed Jun 01, 2005 12:20 pm
Forum: CPAP and Sleep Apnea Message Board
Topic: Heated Humidifier - On or Off?
Replies: 5
Views: 2022

Wow. I'm impressed! Looks like we've found the Heloise of the cpaptalk forum! Thank you very much Linda, but Heloise? I don't think so. Heloise was a woman - the mistress and wife of Abelard (circa 1098-1164). I have a very deep voice (used to sing bass in the church choir) and a very shaggy beard....
by Hugh
Wed Jun 01, 2005 12:06 am
Forum: CPAP and Sleep Apnea Message Board
Topic: Heated Humidifier - On or Off?
Replies: 5
Views: 2022

Heated Humidifier - On or Off?

Problem: With the REMstar Auto (and perhaps other models of xPAP), one cannot easily see green LED lamp that indicates whether or not the heated humidifier is on or off. In my case, the machine is about 5 inches off the floor right next to my bed. When in bed and looking down at the top of the machi...
by Hugh
Thu Mar 24, 2005 8:25 pm
Forum: CPAP and Sleep Apnea Message Board
Topic: Full beard and moustache -- Need non-leaking mask
Replies: 9
Views: 3113

I have my hair cut and beard trimmed every 3 or 4 months. Needless to say, most of the time I look like a shaggy dog! Fortunately, my dear wife likes shaggy dogs.

I have not found that a shaggy beard causes any leaks using the Resmed Ultra Mirage.

... Hugh (AKA Shaggy Dog)
by Hugh
Thu Mar 24, 2005 6:04 pm
Forum: CPAP and Sleep Apnea Message Board
Topic: Full beard and moustache -- Need non-leaking mask
Replies: 9
Views: 3113

I have a 35 year investment in a full beard and I am not about to shave it off! I use the Resmed Ultra Mirage with no problems.