NEW Oscar 2.1.1 is released and available now

General Discussion on any topic relating to CPAP and/or Sleep Apnea.
User avatar
BlueDragon
Posts: 575
Joined: Sun May 27, 2018 10:20 am
Location: Sonoran Desert

NEW Oscar 2.1.1 is released and available now

Post by BlueDragon » Sat Oct 31, 2026 10:41 am

OSCAR  v2.1.1 is released and ready for download.
Quick Link: https://www.sleepfiles.com/OSCAR/

Changes and fixes in OSCAR v2.1.1
  • [new] Headless command line automation for data import
  • [new] Split oximetry data to match CPAP day split
  • [new] Portable mode for Windows allows OSCAR to be run from USB stick or SD card
  • [new] Support Lowenstein Prisma VENT 50-C (experimental)
  • [new] Support Weinmann SOMNObalance e CPAP
  • [new] SpO2 drops can be measured from a rolling, whole night, first hour or fixed baseline; rolling is the new default, and whole night and first hour use a selectable percentile (the median by default)
  • [update] Changing the Oximetry settings now recalculates SpO2 drops and pulse changes for existing data
  • [update] SpO2 drops now record their depth, and flags are recalculated once with the rolling baseline when a profile is opened
  • [fix] Alt+Tab did not work on Linux if mouse was over a graph
  • [fix] At startup confirm that oscar.db is present in its data folder
  • [fix] Internal code improvements
  • [fix] Checkboxes in Preferences/Events and Waveforms now show properly on MacOS
  • [fix] Max pressure was reported incorrectly on Löwenstein Prisma
  • [fix] Löwenstein rebuild from backup deleted data but then couldn't find its backup
  • [fix] Fix ring buffer problem in BMC loader
  • [fix] Don't show empty Insp and Exp Time plots with BMC loader
  • [fix] Some respiratory event rows were duplicated in the database
  • [fix] Mac scrolled too fast with CMD + two-finger pull
  • [fix] Steady Breathing setting is now per-profile rather than global
  • [fix] Since OSCAR 2.1.0, BMC legacy loader extended previous days
  • [fix] Change sleep stage color in calendar from cyan to cream
  • [fix] SpO2 drops in ResMed oximetry data were often missed
  • [fix] ResMed oximetry filled times with no reading with the last SpO2 and pulse value; they are now shown as gaps, and OSCAR offers to rebuild data imported earlier
  • [fix] Invalid ResMed oximetry readings could add a wrong SpO2 or pulse value
  • [fix] Oximeter dropouts were flagged as pulse changes or stretched SpO2 drops
  • [fix] Declining Oximetry Reset Defaults still reset some settings
  • [fix] Automatic Oximetry Cleanup removed SpO2 drop and pulse change flags without recalculating them
  • [fix] Remember secondary sort order of Profiles table, not just last sort
  • [fix] Fix various typos and grammar errors and US vs UK English differences
  • [fix] Support BMC SD card with summary data only
  • [fix] Compressing backups on import of Resmed data with non-Latin characters in path failed
  • [fix] Sefam S.Box was not always reporting AHI and events
  • [fix] Cosmetic changes to Layout dialog
See OSCAR for the latest release.
OSCAR Lead Developer
ResMed AirCurve 10 VAuto, F&P Brevida.
FlashAir SD and FlashPap for data transfer.

User avatar
SleepyCPAP
Posts: 334
Joined: Wed Dec 08, 2010 6:01 am

Re: NEW Oscar 2.1.1 is released and available now

Post by SleepyCPAP » Mon Nov 02, 2026 2:17 pm

Thanks. I’ve finally updated from v 1.4.0

But I don’t see how to navigate to the folder with my O2Ring data in this version. In the ancient version of OSCAR I could see my “Favorites” list where I’d put a shortcut to the serial number folder with all the data files. Can’t see that now. Also can’t find the Library folder to dig down to where it actually resides.

I’m using an M1 MacPro running Sonoma 14.1

- Sleepy
-- SleepyCPAP
Sleep study in 2010 (11cm CPAP). Pillows (Swift FX>TAP PAP >Bleep). PRS1 “Pro” 450/460 until recall, now Aircurve 10 VAuto. Tape mouth. Palatal Prolapse solved by AlaxoStent & VAuto EPAP 4cm, PS 3.6cm = 0.0 AHI

User avatar
BlueDragon
Posts: 575
Joined: Sun May 27, 2018 10:20 am
Location: Sonoran Desert

Re: NEW Oscar 2.1.1 is released and available now

Post by BlueDragon » Tue Nov 03, 2026 1:40 am

There are instructions for importing O2Ring data here: https://www.apneaboard.com/wiki/index.p ... ile_Import

I don't use the Mac myself, so cannot confirm that the documentation is current.

We are in the process of rewriting the oximeter import process and it should be in the next version of OSCAR. This version will import O2Ring data using USB cable, files, or bluetooth. Are you able to use the Intel version of OSCAR? We should have a test version available in a week or so.
See OSCAR for the latest release.
OSCAR Lead Developer
ResMed AirCurve 10 VAuto, F&P Brevida.
FlashAir SD and FlashPap for data transfer.